Our team is highly trained, extremely motivated, and takes great pride in their work.

Our team of professionals is comprised of highly qualified engineers; NICET certified, designers, technicians, and experienced drafters, along with a skillful field personnel ready to provide an excellent quality service.

What fire protection services do we offer?

Our services include the design, manufacturing, installation, and inspection of different types of fire protection systems.

A fire sprinkler system is considered an Active Fire Protection Method, consisting of a water supply system, providing adequate pressure and flowrate to a water distribution piping system, onto which fire sprinklers are connected.

Fire protection should be a major consideration for any building owner, regardless of the type of business, occupancy, or size of the structure. A fire sprinkler system can significantly reduce a fire's rate of growth and the risk of fatalities and injuries. As a result, the installation of a fire sprinkler system can be one of the most important investments a building owner makes.

Automatic Fire Sprinklers Systems

The fire pump is a vital part of a building's fire suppression system. It is responsible for pulling water from some dedicated source—either an underground public water supply main or a water source, such as a well, water-storage tank, lake, or other body of water—into the building in the event of a fire.

Our fire pump system design and installation services, ensure that you have the fire protection you need and that the pumps are engineered to properly support the sprinklers installed in your property. We will design a fire pump system for your building that meets NFPA code requirements and complies with your local fire codes.

Automatic Fire Sprinklers Systems

A foam water fire sprinkler system is a special application system, typically discharging a mixture of water and low expansion foam concentrate, resulting in a foam spray from the sprinkler nozzle. These systems are usually used with special hazards occupancies associated with high challenge fires, such as flammable liquids, and airport hangars. Operation is as described above, depending on the system type into which the foam is injected.

While there is no such a thing as a standard fire supression system, foam systems designed and installed by Prime Fire, are guaranteed to be nothing but the best. Allow Prime Fire to become your competent and certified fire supression contractor!

Automatic Fire Sprinklers Systems

This system is designed to meet the requirements of NFPA 2001, Standard for Clean Agent Fire Extinguishing Systems, 2001 edition. It is suitable for a wide range of property types, including industrial and commercial occupancy. System components are designed to be mounted on standard ISO-approved pipework and fire protection system enclosures.

The fire suppressing system is activated by heat, smoke, or a combination of the two. The system is designed around three basic elements: a means for delivering the extinguishment agent, a discharge piping system, and a discharge nozzle or nozzles. Each of these elements is an important consideration in the design of a suppression system.

Automatic Fire Sprinklers Systems

A smoke detector is a device that senses smoke, typically as an indicator of fire. Commercial smoke detectors issue a signal to a fire alarm control panel as part of a fire alarm system. Prime Fire is a proud Honeywell's NOTIFIER Engineered System Distributor(ESD) for the Caribbean, meaning that we sell and install the industry's premier fire alarm system brand.

Therefore, the equipment that we supply, coupled with our experience in the industry, our attention to detail and our commitment to quality,they all make us the perfect choice for any commercial or industrial fire alarm system.

Automatic Fire Sprinklers Systems

Having a suitable program of inspection, testing, and maintenance (ITM) is one of the more important steps to be taken to assure the success of the fire protection system. The truth is, when an appropriate level of inspection, testing, and maintenance is taking place, this activity will directly contribute to the high level of reliability expected and could extend the lifespan of your fire protection system. The purpose of the ITM program is to discover failures of components that would prevent the fire system from operating as necessary during a fire or emergency event. And of course, the goal is to discover and repair these failures prior to such an event.

The primary standard in use in most companies is NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems. NFPA 25 establishes the minimum requirements for the periodic inspection, testing, and maintenance of water-based fire protection systems. As for the fire alarm systems, NFPA72 is the standard utilized to establish ITM compliance for fire alarm systems.

Automatic Fire Sprinklers Systems

Fire Departments use Fire Hose Systems to operate the fire hose that carries water from hydrants to the fire itself. Fire Hose Systems typically consist of a fire hose reel that is permanently installed in the fire main and a fire hose cabinet that houses the fire hose reel, fittings, and accessories. Fire Hose Systems may also include a fire hose support assembly, which supports the fire hose in a safe, convenient location.

Prime Fire's Fire Hose System design and installation services are essential components of any commercial establishment. We are a reliable company that has been in the business for over 25 years. We believe in quality workmanship and ensure that the services we provide meet or exceed our customers' expectations.

Automatic Fire Sprinklers Systems